Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 613
Filtrar
1.
J Forensic Sci ; 69(1): 365-370, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37888147

RESUMO

A 28-year-old man was admitted dead to the emergency department of the regional hospital. All resuscitation attempts were unsuccessful in this case. Attending officers stated that he was suspected of possessing drugs at the time of arrest and had taken them quickly to cover up. Upon arrival at the hospital, signs of violence were noted all over his body. During the autopsy, two large blue plastic packages were found in the antrum of the stomach. The first was 6.3 × 2.2 cm and had two tight knots, while the second was 7.6 x 1.7 cm and had a single knot. Both packages were irregularly shaped and contained tablet debris that was clearly leaking, as a large amount of gastric juice was present in both packages. A confirmatory forensic toxicology analysis revealed toxic concentrations of methamphetamine in the blood of the dissected case. The patient died of acute methamphetamine intoxication associated with a severe stress condition resulting from violent resistance during arrest.


Assuntos
Transporte Intracorporal de Contrabando , Corpos Estranhos , Metanfetamina , Masculino , Humanos , Adulto , Corpos Estranhos/complicações , Metanfetamina/análise , Estômago/química , Autopsia
2.
J Anal Toxicol ; 48(1): 75-80, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-37952092

RESUMO

A new class of synthetic cannabinoids called OXIZIDs has emerged in recent years. This class consists of compounds with oxindole cores and hydrazide/hydrazone linker moieties and has often been described as being designed to circumvent a Chinese class-wide ban that was effective as of 1 July 2021. However, through hair testing of nightclub attendees in New York City-a high-risk population for recreational drug use-we have evidence suggesting exposures to an OXIZID called BZO-4en-POXIZID (4en-pentyl MDA-19) prior to the effective ban. Through analysis of 6 cm segmented hair samples from attendees collected in 2021, we detected five cases of exposure. Specifically, we detected a cluster of three cases based on hair samples collected on 20 June 2021, and then two additional cases from samples collected on 16 July 2021. Four of these hair samples were long enough to analyze two 6 cm hair segments (representing approximately two 6-month timeframes) and three of four of these cases tested positive for repeated exposure (for an estimated exposure over 6 months prior to hair collection). All cases included young adult females reporting past-year cannabis use but all tested negative for tetrahydrocannabinol exposure. Three cases also reported past-year use of cocaine, ecstasy, and/or ketamine, and four cases tested positive for exposure to cocaine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine and/or eutylone. These subjects were exposed to BZO-4en-POXIZID-likely as an adulterant in other drugs, and these cases are among the first documented cases which occurred approximately half a year before the Chinese legislative ban.


Assuntos
3,4-Metilenodioxianfetamina , Cocaína , Drogas Ilícitas , Metanfetamina , N-Metil-3,4-Metilenodioxianfetamina , Feminino , Adulto Jovem , Humanos , Cidade de Nova Iorque/epidemiologia , Drogas Ilícitas/análise , N-Metil-3,4-Metilenodioxianfetamina/análise , Metanfetamina/análise , 3,4-Metilenodioxianfetamina/análise , Cocaína/análise
3.
Se Pu ; 41(12): 1141-1148, 2023 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-38093545

RESUMO

Amphetamine-type drugs are synthetic compounds with an amphetamine parent structure. These compounds cause addiction, central nervous system excitation, and hallucinations. The number of drug users worldwide has gradually increased because amphetamine-type drugs can be synthesized in a simple and artificial manner. The current methods for anti-drug screening and toxicant identification are limited by the large quantity and variety of the drug analytes and long detection times. Thus, the development of broad-spectrum, rapid, and high-throughput detection methods is an urgent necessity. In addition, conventional amphetamine-type drug test samples, such as blood and urine, are only suitable for short-term drug identification. Hair has the advantages of easy preservation, stability, and a long detection window, which can compensate for the deficiencies of body-fluid-based test materials. Hair samples can reflect long-term drug use, which is beneficial for tracing drug sources, and has become an important means of providing evidence in court. Because most laboratory instruments are unable to perform the rapid on-site detection of amphetamine-type drugs in hair, establishing a high-throughput, qualitative and quantitative rapid on-site detection method is necessary. In this study, pulsed direct current electrospray ionization (Pulsed-DC-ESI) coupled with mass spectrometry was used for the rapid detection of four amphetamine-type drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in hair. Methanol was used as the extraction solvent, and the grinding method was used for extraction. The pretreatment process included cutting, grinding, and centrifugation. The pretreatment time for each sample was about 10 min. Multiple samples could be processed in batches, greatly improving the efficiency of analysis. Pulsed-DC-ESI is an ambient ionization technology that can be conducted via direct injection without chromatographic separation. The tip of the spray capillary tube was immersed 1 cm below the surface of the sample solution to allow absorption via the capillary effect. When the spray capillary tube contained 1 µL of the sample solution, detection was performed. Pulsed-DC-ESI generates an electrospray at the same frequency as the mass spectrum, thereby avoiding the problem of sample wastage, which often occurs in traditional ESI. The portable mass spectrometer used for analysis is a linear ion trap mass spectrometer. The parameters of Pulsed-DC-ESI, such as the inner diameter of spray capillary tip, spray voltage, and distance between electrode and solution, were optimized based on the mass spectral responses of the amphetamine-type drugs. The optimized ion source conditions included a inner diameter of spray capillary tip of 25 µm, spray voltage of 2 kV, and the distance between electrode and solution of 20 mm. The optimal sample solvent was methanol. The optimized method can achieve simultaneous detection of the four amphetamine-type drugs within 20 s. The linear ranges of amphetamine, methamphetamine, and the two other drugs were 1-25, 1-100, and 1-50 ng/mg, respectively. The limits of detection and quantification of the four drugs in hair were 0.1-0.2 and 1 ng/mg, respectively. All linear correlation coefficients were greater than 0.99, and the average spiked recoveries were 86.6%-114.7%. The intra-day precisions were 4.14%-7.34%, and the inter-day precisions were 3.71%-8.43%. The proposed method was used to screen 2000 samples provided by various testing institutions. A total of five samples were positive for methamphetamine, which is consistent with the results of conventional forensic identification methods. Thus, the developed method can be used for the rapid detection of amphetamine-type drugs.


Assuntos
Anfetamina , Metanfetamina , Anfetamina/análise , Espectrometria de Massas por Ionização por Electrospray , Metanol/análise , Metanfetamina/análise , Cabelo/química , Solventes/análise
4.
Rev Neurol ; 77(12): 293-298, 2023 Dec 16.
Artigo em Espanhol | MEDLINE | ID: mdl-38095053

RESUMO

INTRODUCTION: Chronic non-recreational use of methamphetamine (shabu) is increasing among the Filipino population in Barcelona. The Asian population presents a different stroke pattern, with a higher incidence of haemorrhage, and different vascular risk factors and health behaviours. The objective of this study is to describe the stroke profile and incidence of methamphetamine use in patients of Filipino origin admitted to our centre. PATIENTS AND METHODS: Demographic data, vascular risk factors, clinical data and prognosis were recorded. Methamphetamine exposure was analysed in plasma samples collected on admission, which were then analysed by liquid chromatography-mass spectrometry. RESULTS: Of a total of 6,418 stroke patients, 73 (1.1%) were identified as being of Filipino origin. The mean age was 54.4 ± 12.1 years, 54% were male and the stroke was ischaemic in 64.4% of cases. Arterial hypertension was the main risk factor. Ten (13.7%) patients tested positive for methamphetamine and amphetamine. These results confirm recent substance use prior to the stroke, mostly in men (80%). In patients who were consumers, 60% had a haemorrhagic stroke, with a poor functional prognosis at three months in 55.6% of patients. CONCLUSIONS: In our setting, patients of Filipino ethnicity admitted for stroke related to the consumption of shabu belonged a younger age bracket, with a lower prevalence of vascular risk factors and a predominance of the haemorrhagic subtype. Methamphetamine testing in Filipino stroke patients is recommended due to the high prevalence of methamphetamine use in our country.


TITLE: Perfil clínico y abuso de metanfetamina no recreativa (shabú) entre los pacientes con ictus en la población filipina.Introducción. En la población filipina de Barcelona está aumentando el consumo crónico no recreativo de metanfetaminas (shabú). La población asiática presenta un patrón de ictus diferente, con mayor incidencia de hemorragias, y diferentes factores de riesgo vascular y conductas de salud. El objetivo es describir el perfil de ictus e incidencia de consumo de metanfetaminas en pacientes de origen filipino ingresados en nuestro centro. Pacientes y métodos. Se registraron datos demográficos, factores de riesgo vascular, datos clínicos y pronóstico. Se analizó la exposición a metanfetamina en muestras de plasma recogidas en el ingreso, que se analizaron por cromatografía líquida-espectrometría de masas. Resultados. Del total de 6.418 pacientes con ictus, se identificó a 73 pacientes filipinos (1,1%). La edad media era de 54,4 ± 12,1 años, el 54% eran hombres y el ictus era isquémico en el 64,4%. La hipertensión arterial fue el principal factor de riesgo. Diez (13,7%) pacientes dieron positivo a metanfetamina y anfetamina. Estos resultados confirman un consumo reciente de sustancias previo al ictus, principalmente en hombres (80%). En pacientes consumidores, un 60% presentaba un ictus hemorrágico, con mal pronóstico funcional a tres meses en el 55,6% de los pacientes. Conclusiones. En nuestro medio, los pacientes de etnia filipina ingresados por ictus en relación con consumo de shabú presentaron un perfil de edad más joven, con menor prevalencia de factores de riesgo vascular y predominio del subtipo hemorrágico. Se recomienda la determinación de metanfetamina en los pacientes filipinos con ictus debido a la alta prevalencia del consumo de metanfetamina en nuestro país.


Assuntos
Transtornos Relacionados ao Uso de Anfetaminas , Metanfetamina , Acidente Vascular Cerebral , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Filipinas/epidemiologia , Metanfetamina/efeitos adversos , Metanfetamina/análise , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Transtornos Relacionados ao Uso de Anfetaminas/complicações , Transtornos Relacionados ao Uso de Anfetaminas/epidemiologia , Anfetamina
5.
Anal Methods ; 15(46): 6482-6491, 2023 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-37987503

RESUMO

This study was focused on the development of a sensitive, reliable, and efficient extraction procedure for the determination of amphetamine and methamphetamine utilized in the adulteration of creatine sports supplements. The separation and detection of the analytes were conducted using the gas chromatography-flame ionization detection method. In this study, the analytes were extracted from a supplement powder into a proper solvent by sonication. Then, the extract was mixed with butyl chloroformate to obtain their butylated derivatives and then concentrated by a dispersive liquid-liquid microextraction procedure. The method was performed in a short time. Under optimized extraction conditions, a linear range of 2.01-500 ng g-1 was obtained by a coefficient of determination ≥0.996. Low detection (0.22 ng g-1 and 0.61 ng g-1 for amphetamine and methamphetamine, respectively) and quantification (0.73 ng g-1 and 2.01 ng g-1 for amphetamine and methamphetamine, respectively) limits, good precision (relative standard deviations ≤8.2%), and high extraction recoveries (79% and 86% for amphetamine and methamphetamine, respectively) were achieved. The usefulness of the method in the analysis of the target compounds was confirmed by studying the matrix effect and analysis of the analytes in different real samples.


Assuntos
Microextração em Fase Líquida , Metanfetamina , Metanfetamina/análise , Anfetamina/análise , Creatina/análise , Microextração em Fase Líquida/métodos , Cromatografia Gasosa/métodos
6.
Anal Methods ; 15(42): 5692-5699, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37861716

RESUMO

Colloidal gold immunoassay is the most widely used method in the field of drug detection. However, this method often has poor quantitative identification ability and low analytical sensitivity, which is not suitable for the analysis of hair poisoning ingredients. In order to solve these limitations, we developed an immunochromatographic test strip for simultaneously screening multiple drugs in this study. This hand-held test strip used fluorescent nanoparticles loaded with lanthanide chelates as the signal carrier of fluorescence reading, and conducted quantitative testing of various drugs based on the competitive immune reaction between the analyte and antigen. Under the optimal conditions, the competition curves of morphine (MOP), methamphetamine (MET) and ketamine (KET) were obtained on a single band. The detection limit (LOD) of this analytical method was 100-1000 times lower than that of colloidal gold test strips. The detection limits of MOP, MET and KET were 0.06 ng mL-1, 0.1 ng mL-1 and 1.0 ng mL-1, respectively. No cross-reaction was observed when morphine, methamphetamine and ketamine were tested simultaneously with this method. And 184 hair samples were tested simultaneously, and the detected amount was very close to the results of LC-MS. The immunochromatographic strip showed good stability in repeated tests, and the coefficient of variation was less than 15%. Fluorescence immunochromatography strips and handheld strip readers have the characteristics of portability, speed, ease of operation and high sensitivity, and may become powerful tools for screening drug abuse in hair in forensic medicine.


Assuntos
Ketamina , Elementos da Série dos Lantanídeos , Metanfetamina , Morfina/análise , Limite de Detecção , Metanfetamina/análise , Cromatografia de Afinidade/métodos , Coloide de Ouro/química , Cabelo/química
7.
Sci Total Environ ; 905: 166910, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-37689196

RESUMO

Wastewater-based epidemiology (WBE) has emerged as an effective method for monitoring a community's health status and lifestyle. In recent years, enantiomeric profiling has shown promise as a tool for tracing the sources of abused drugs through WBE. This study investigated amphetamine (AMP) and methamphetamine (METH) consumption in South Korea using enantiomeric analysis of untreated wastewater samples collected from 27 wastewater-treatment plants (WWTPs). Both AMP and METH were detected, with the predominant detection of S-(+)-METH indicating widespread illegal use of METH, which is primarily produced by a clandestine synthesis procedure that involves the reduction of ephedrine/pseudoephedrine. Most AMP/METH ratios in the samples were consistent with the expected METH excretion profile, indicating that the presence of AMP was primarily due to METH metabolism. However, R-(-) AMP was detected in 18.5 % and 25.9 % of wastewater samples in winter and spring, respectively, and the high AMP/METH ratio (>0.27) indicated potential AMP abuse. By differentiating between the sources of AMP and METH in wastewater, enantiomeric analysis could help authorities to target and address specific drug-abuse issues affecting the population more effectively.


Assuntos
Metanfetamina , Poluentes Químicos da Água , Metanfetamina/análise , Águas Residuárias , Detecção do Abuso de Substâncias/métodos , Anfetamina/análise , República da Coreia , Poluentes Químicos da Água/análise
8.
Water Res ; 244: 120452, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37604019

RESUMO

Drug consumption in prisons is a concern for the safety of incarcerated people and staff. Typically, drug use prevalence in prisons is estimated through urinalysis and intelligence operations, which can be intrusive and stressful. An alternative approach, wastewater-based epidemiology (WBE), was used in this study to estimate the consumption of licit and illicit drugs for the entire population of a prison in Australia. Wastewater samples were collected from March to December 2020, covering periods of no restrictions and periods when prison access was restricted to prevent the transmission of COVID-19. Target biomarkers were analysed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The average consumption of common illicit drugs (MDMA, methamphetamine and cocaine) over the sampling period in the prison (0.5 - 4.5 mg/1000 people/day) was two to three orders of magnitude lower than in the community population (254 - 1000 mg/1000 people/day). Comparison of WBE estimates against pharmacy dispensing data suggested potential illicit buprenorphine consumption at the prison. Methamphetamine and buprenorphine use decreased when no visitors were allowed (18% - 72% decrease for methamphetamine; about half decrease for buprenorphine) and increased once these restrictions were eased (22% - 39% increase for methamphetamine; 44% - 67% increase for buprenorphine). The changes in drug use may be attributed in part to a reduction of drug trafficking into the prison from visitors or non-essential staffs and in part to the reduced contribution of urine from staff who used toilets within the prison. This study provided useful information on the scale of illicit drug use and extra-medical use of licit drugs in prison, and its changes under different security conditions.


Assuntos
Buprenorfina , COVID-19 , Drogas Ilícitas , Metanfetamina , Transtornos Relacionados ao Uso de Substâncias , Poluentes Químicos da Água , Humanos , Drogas Ilícitas/análise , Prisões , Águas Residuárias , Cromatografia Líquida , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem , COVID-19/epidemiologia , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Metanfetamina/análise , Poluentes Químicos da Água/análise , Buprenorfina/análise
9.
J Forensic Sci ; 68(6): 2093-2102, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37650474

RESUMO

Cocaine and methamphetamine remain highly abused drugs in the United States due to their euphoric effects. This study examines classical stimulant casework, defined as cases positive for methamphetamine and/or cocaine, received by the Toxicology Laboratory and the Drug Analysis Laboratory at the Dallas County Southwestern Institute of Forensic Sciences from local law enforcement agencies and/or the Office of the Medical Examiner (OME) between January 1, 2017, and December 31, 2022. Methamphetamine positivity increased from 10.4% to 20.3% in the Toxicology Laboratory over the 6 years, whereas cocaine positivity remained relatively stable at approximately 17%. Similarly, in the Drug Analysis Laboratory, the methamphetamine positivity rate changed from 24.8% to 33.2%, whereas cocaine identification remained stable at approximately 20%. Blood concentrations of methamphetamine in OME cases ranged from 10.1-42,740.0 ng/mL while they were lower in DWI casework ranging from 10.2-2385.0 ng/mL. The blood concentration trends of cocaine were similar to methamphetamine, with OME casework ranging higher (10.0-24,501.0 ng/mL) than DWI casework (10.2-371.6 ng/mL). Polydrug use was evident for both methamphetamine and cocaine in postmortem cases, and the top three most frequently co-occurring drug/drug class were opioids/opiates, cannabinoids, and ethanol. The results from this study aid in the understanding of historical usage trends of cocaine and methamphetamine in Dallas County and how those trends have changed over time as newer stimulant drugs have emerged.


Assuntos
Estimulantes do Sistema Nervoso Central , Cocaína , Metanfetamina , Transtornos Relacionados ao Uso de Substâncias , Humanos , Estados Unidos , Estudos Retrospectivos , Cocaína/análise , Metanfetamina/análise , Transtornos Relacionados ao Uso de Substâncias/epidemiologia
10.
Chemosphere ; 339: 139668, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37517667

RESUMO

Residues of illicit drugs are frequently detected in wastewater, but data on their removal efficiency by wastewater treatment plants (WWTPs) and the ecological risks to the aquatic environment are lacking in this study. The research evaluates the residues, mass load, drug removal efficiency, and risk assessment of illicit drugs in WWTPs and aquatic environments (lakes) in Xinjiang, China. Initially, the concentration (incidence) and mass load of 10 selected illicit drugs were analyzed through wastewater analysis. The detected substances included methamphetamine (METH), morphine (MOR), 3,4-methylenedioxy methamphetamine (MDMA), methadone (MTD), cocaine (COC), benzoylecgonine (BE), ketamine (KET), and codeine (COD), with concentrations ranging from 0.11 ± 0.01 ng/L (methadone) to 48.26 ± 25.05 ng/L (morphine). Notably, morphine (59.74 ± 5.82 g/day) and methamphetamine (41.81 ± 4.91 g/day) contributed significantly to the WWTPs. Next, the drug removal efficiency by different sewage treatment processes was ranked as follows: Anaerobic-Oxic (A/O) combined Membrane Bio-Reactor (MBR) treatment process > Oxidation ditch treatment process > Anaerobic-Anoxic-Oxic (A2/O) treatment process > Anaerobic-Anoxic-Oxic combined Membrane Bio-Reactor treatment process. Finally, the research reviewed the concentration and toxicity assessments of these substances in the aquatic environment (lakes). The results indicated that Lake1 presented a medium risk level concerning the impact of illicit drugs on the aquatic environment, whereas the other lakes exhibited a low risk level. As a result, it is recommended to conduct long-term monitoring and source analysis of illicit drugs, specifically in Lake1, for further investigation. In conclusion, to enhance the understanding of the effects of illicit drugs on the environment, future research should expand the list of target analytes.


Assuntos
Drogas Ilícitas , Metanfetamina , Poluentes Químicos da Água , Purificação da Água , Águas Residuárias , Eliminação de Resíduos Líquidos/métodos , Drogas Ilícitas/análise , Rios , Poluentes Químicos da Água/análise , Metanfetamina/análise , Purificação da Água/métodos , Medição de Risco , Derivados da Morfina/análise , China
11.
J Forensic Sci ; 68(4): 1268-1276, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37149745

RESUMO

Bone samples are valuable for examining the cause of death and circumstance leading up to death when body fluids are not available for forensic toxicological analysis. Examined were heat-induced changes in methamphetamine and amphetamine concentrations in femurs removed from methamphetamine-injected mice to determine if the burned bones could be used for toxicology testing. The femurs were heated at 100°C, 300°C, or 500°C for 10 or 30 min. The tissue structure of the heated femurs was preserved at 100°C for 30 min but was destructed at higher temperatures. Methamphetamine and amphetamine were detected in femurs heated at 100°C for 10 min, 100°C for 30 min, and 300°C for 10 min (with methamphetamine and amphetamine concentrations ranging from 0.36 to 35 µg/g and 0.54 to 47 µg/g, respectively). Methamphetamine and amphetamine were detectable when heated above their decomposition temperature as a result of limited heat transfer do to protection provide by the femoral muscle. Thus, the bone could be a useful analytical sample in cases of burn-related deaths, where it is difficult to collect body fluids.


Assuntos
Metanfetamina , Animais , Camundongos , Anfetamina/análise , Fêmur/química , Temperatura Alta , Metanfetamina/análise , Temperatura
12.
Sci Total Environ ; 889: 164310, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37211103

RESUMO

Understanding the consumption patterns of substances with abuse potential in the population is critical in combating drug crimes in the region. In recent years, wastewater-based drug monitoring has become a complementary tool worldwide. This study aimed to use this approach to understand the long-term consumption patterns of abuse potential substances in Xinjiang, China (2021-2022) and to provide more detailed and practical information on the current system. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to quantify the levels of abuse potential substances in wastewater. Subsequently, the detection rate and contribution rate of the drug concentrations were evaluated through analysis. Eleven of abuse potential substances were detected in this study. The influent concentrations ranged from (0.48 ng/L) to 133.41 ng/L, with dextrorphan having the highest concentration. The highest detection frequency rates were for morphine (82 %), dextrorphan (59 %), 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (43 %), methamphetamine (36 %), and tramadol (24 %). According to a study on wastewater treatment plants (WWTPs) removal efficiency, compared to the total removal efficiency in 2021, the total removal efficiency of WWTP1, WWTP3, and WWTP4 increased in 2022, while WWTP2 decreased slightly, and WWTP5 did not change significantly. Upon examination of the use of 18 selected analytes, it was determined that methadone, 3,4-methylenedioxy methamphetamine, ketamine, and cocaine were the primary substances of abuse in the Xinjiang region. This study identified significant abuse substances in Xinjiang and identified research priorities. Future studies should consider expanding the study site to obtain a comprehensive understanding of the consumption patterns of these substances in Xinjiang.


Assuntos
Metanfetamina , Poluentes Químicos da Água , Águas Residuárias , Espectrometria de Massas em Tandem , Dextrorfano/análise , Poluentes Químicos da Água/análise , Metanfetamina/análise , China
13.
J Anal Toxicol ; 47(4): 346-352, 2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-36611270

RESUMO

In forensic toxicology, hair has become a hot biological material for drug testing due to its wider detection window and noninvasive sampling process compared to traditional liquid biological materials (e.g., blood and urine). However, hair as a matrix differs from body fluids, as it is not as easily aliquoted for analysis. Nevertheless, pretreatment methods for hair detection have gradually improved from the first chemical methods, such as alkali digestion and acid hydrolysis, to now include the physical method of pulverization and further improvements beyond "pulverization" protocols. In a previous study, we updated and developed a "micropulverized extraction" method. In the present study, our aim was to gain a more complete understanding of the "micropulverized extraction" method by comparing pulverization temperature and hair particle size, as these two factors are known to influence the effectiveness of sample processing. The analytes we selected were those commonly encountered in traditional drug abuse cases: (±)-methamphetamine, (±)-amphetamine, morphine, 6-acetylmorphine, cocaine, benzoylecgonine, (--)-∆9-tetrahydrocannabinol, ketamine, (±)-norketamine and (±)-3,4-methylenedioxymethamphetamine. The analysis method was liquid chromatography-tandem mass spectrometry.


Assuntos
Drogas Ilícitas , Metanfetamina , N-Metil-3,4-Metilenodioxianfetamina , Drogas Ilícitas/análise , Anfetamina/análise , Metanfetamina/análise , N-Metil-3,4-Metilenodioxianfetamina/análise , Detecção do Abuso de Substâncias/métodos , Cabelo/química
14.
Talanta ; 255: 124208, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36628903

RESUMO

Methamphetamine (MA) is a synthetic psychoactive drug which is consumed both licitly and illicitly. In some countries it is prescribed for attention-deficit and hyperactivity disorder, and short-term treatment of obesity. More often though, it is abused for its psychostimulant properties. Unfortunately, the spread and abuse of this synthetic drug have increased globally, being reported as the most widely consumed synthetic psychoactive drug in the world in 2019. Attempting to overcome the shortcomings of the currently used on-site methods for MA detection in suspected cargos, the present study explores the potential of electrochemical identification of MA by means of square wave voltammetry on disposable graphite screen-printed electrodes. Hence, the analytical characterization of the method was evaluated under optimal conditions exhibiting a linear range between 50 µM and 2.5 mM MA, a LOD of 16.7 µM, a LOQ of 50.0 µM and a sensitivity of 5.3 µA mM-1. Interestingly, two zones in the potential window were identified for the detection of MA, depending on its concentration in solution. Furthermore, the oxidative pathway of MA was elucidated employing liquid chromatography - mass spectrometry to understand the change in the electrochemical profile. Thereafter, the selectivity of the method towards MA in mixtures with other drugs of abuse as well as common adulterants/cutting agents was evaluated. Finally, the described method was employed for the analysis of MA in confiscated samples and compared with forensic methods, displaying its potential as a fast and easy-to-use method for on-site analysis.


Assuntos
Estimulantes do Sistema Nervoso Central , Metanfetamina , Metanfetamina/análise , Cromatografia Líquida , Medicina Legal , Eletrodos , Psicotrópicos/análise
15.
J Anal Toxicol ; 47(2): 197-205, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35900095

RESUMO

Amphetamines (AMPs) in hair were investigated with thousands of workplace testing head and body hair samples collected and analyzed over 10 years and tabulated by year. All samples were washed by a published extensive method prior to confirmation by liquid chromatography-mass spectrometry-mass spectrometry. Presented are concentrations of parent methamphetamine (METH), 3,4-methylenedioxymethamphetamine (MDMA) and methylenedioxyamphetamine as metabolite and AMP as metabolite and without the presence of parent drug. Some differences in METH concentrations from year to year were significant, and some ratios of metabolite to parent drug for both METH and MDMA also varied significantly. While rates of METH use may not have changed significantly, some aspects of the drugs ingested as demonstrated by hair analysis varied over the 10-year period.


Assuntos
Metanfetamina , N-Metil-3,4-Metilenodioxianfetamina , N-Metil-3,4-Metilenodioxianfetamina/análise , Detecção do Abuso de Substâncias/métodos , Anfetaminas/análise , Metanfetamina/análise , Cabelo/química , Local de Trabalho
16.
J Anal Toxicol ; 47(1): 52-58, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35445258

RESUMO

The emergence of novel drugs and the continuous expansion of the scope of the types of drugs under control have greatly increased requests for screening of a range of drugs in hair. Here, a multi-analyte method for the detection and quantification of 88 psychotropic drugs in the hair of addicts in drug abstinence was developed and fully validated using liquid chromatography-tandem mass spectrometry (LC-MS-MS). Hair samples (25 mg) were washed, cut into pieces, cryogenically ground and extracted in methanol. The extracted analytes were separated on an Allure PFP Propyl column (100 × 2.1 mm, 5 mm inside diameter, Restek, USA) and analyzed by LC-MS-MS in multiple reaction monitoring modes. The limits of detection and the limits of quantification ranged from 0.1 to 20 pg/mg and 0.2 to 50 pg/mg, respectively. The intra- and inter-assay precisions (relative standard deviation (RSD)) of all analyses ranged from 0.9% to 14.9% and 1.9% to 15.9%, respectively. Accuracy values were 100 ± 20%. The extraction recovery of quality control samples ranged from 50.9% to 99.6% for all analytes. The matrix effects for all analytes ranged from 46.8% to 99.7%. The method was successfully used to analyze 1,865 hair samples from addicts in drug rehabilitation at their own communities. Among the samples, 129 cases were positive; the majority of positive cases were from males (78.29%), 92.25% of whom were >35 years old. Traditional drugs, like methamphetamine and opioids, accounted for most positive cases, and 27 of the abstinence cases with a use history of methamphetamine were still positive. In addition to abused drugs, like methamphetamine, morphine and cocaine, the sedative-hypnotic and psychotherapeutic drugs, including clonazepam, alprazolam, estazolam, zolpidem and quetiapine, were detected in 26% of the hair samples, suggesting that these addicts may have insomnia and mental problems such as depression and psychosis, probably due to the long-term effects of drugs and withdrawal reactions. Three synthetic cannabinoids were also detected in four (2.7%) cases. A total of 37 cases were positive for methadone, tramadol and dextromethorphan, reflecting a new trend of alternative drug use when traditional drugs were not easy to obtain during the coronavirus disease 2019 outbreak.


Assuntos
COVID-19 , Metanfetamina , Humanos , Adulto , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Metanfetamina/análise , Cabelo/química , Psicotrópicos/análise , Detecção do Abuso de Substâncias/métodos
17.
IEEE Trans Nanobioscience ; 22(1): 38-44, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35085088

RESUMO

Methamphetamine is a powerful stimulant drug, the abuse of which threatens human health and social stability. Rapid and accurate quantification of methamphetamine is essential to inhibit the abuse and prevalence of methamphetamine effectively. In this paper, we present a portable fluorescence reader with upconverting nanoparticle-labeled lateral flow immunoassay (LFIA) for rapid and accurate quantification of methamphetamine. Based on specific binding of a methamphetamine antigen to an antibody in the LFIA, the fluorescence reader is designed to capture and record the fluorescence intensities T and C of the test and control lines, respectively, and the T/C ratio is calculated to determine the concentration of methamphetamine. The linear range for methamphetamine is 0.1-100 ng/mL. Because the sensor is often susceptible to noise interference, using only the T/C ratio to distinguish weakly positive and negative samples of methamphetamine renders the results inaccurate. To solve this problem, we applied a convolutional neural network (CNN) to learn image features of different methamphetamine concentrations (0, 0.01, 0.05, 0.1, and 0.5 ng/mL) for accurate detection of weakly positive and negative samples. The results show that the proposed method can effectively detect weakly positive and negative samples of methamphetamine with an accuracy of up to 92%. The CNN provides a novel scheme for accurate analysis of weakly positive and negative samples in upconverting nanoparticle-labeled LFIA.


Assuntos
Técnicas Biossensoriais , Metanfetamina , Humanos , Metanfetamina/análise , Redes Neurais de Computação , Imunoensaio/métodos
18.
Environ Sci Pollut Res Int ; 30(8): 21815-21824, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36279058

RESUMO

The Qinghai-Tibet Plateau is the third pole of the world, and information on the consumption of psychoactive substances (PSs) in this area is scarce. In this study, we selected Qinghai Province as the research area, and the per capita consumption and prevalence of PSs were investigated using wastewater-based epidemiology. Samples from 17 wastewater treatment plants (WWTPs) in 5 major cities in Qinghai Province were monitored, and 11 PSs were detected by ultra-high performance liquid chromatography-tandem mass spectrometry. Results showed that the target compounds were detected in all samples, with relatively high concentrations of ephedrine (2.1-4825.3 ng/L) and methamphetamine (1.5-295.7 ng/L). The consumption of methamphetamine in Xining City, Haidong City, and Haixi City was up to 78.4, 16.8, and 21.2 mg/1000 inh/d (the PS consumption per 1000 inhabitants in 1 day), respectively, higher than that in the other two cities, which was the result of the different consumption patterns and its relationship with the economic levels of each city. High consumption of methadone (47.9 mg/1000 inh/day) was found in Xining City, which might be related to the methadone maintenance therapy sites in the city. Methamphetamine was the most prevalent drug, with the prevalence ranging from 0.003 (Guoluo) to 0.197% (Xining), and the prevalence of other PSs was low. The ecological risk assessment of PSs in the effluent of WWTPs showed that methadone exerted a low risk to aquatic organisms in three sites, while other substances posed potential risk or no risk. However, the long-term effect of PSs cannot be ignored.


Assuntos
Metanfetamina , Poluentes Químicos da Água , Águas Residuárias , Tibet , Metanfetamina/análise , Espectrometria de Massas em Tandem/métodos , Metadona , Poluentes Químicos da Água/análise
19.
J Pharmacol Toxicol Methods ; 119: 107212, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36028047

RESUMO

INTRODUCTION: It is known that drug abuse jeopardizes economic and social development. Toxicological analyses can guide prevention and treatment strategies in rehabilitation facilities. The current greatest challenge is finding easily adaptable and less costly sensitive methods that meet the principles of green chemistry. Hair, as a biological matrix, has several advantages, and its ability to detect consumption for longer periods keeping the matrix stable and unaltered stands out. This manuscript addresses the use of a miniaturized technique in an alternative matrix, by making use of a reduced amount of solvents to quantify amphetamines, aiming to guide prevention and treatment strategies in rehabilitation facilities. METHODS: A Hollow Fiber Liquid-phase Microextraction (HF-LPME) technique for extracting amphetamines from hair samples with Gas Chromatography-Mass Spectrometry (CG-MS) was validated, adapted, and applied to ten samples from patients of a rehabilitation facility. RESULTS: The technique proved to be sensitive, accurate, precise, and not affected by interference from the biological matrix and the linear range for the analytes was 0.2 to 20 ng mg -1. The three analytes were quantified in the samples analyzed. It is worth stressing that the patients were young. CONCLUSION: The HF-LPME-GC-MS technique complied with the principles of green chemistry, and proved to be a sensitive technique, adaptable to the routine of common laboratories. Validation in the analysis phase with authentic samples, thus, showed that it can be an important tool for preventing and controlling drug addiction.


Assuntos
Metanfetamina , N-Metil-3,4-Metilenodioxianfetamina , Transtornos Relacionados ao Uso de Substâncias , Humanos , Metanfetamina/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Anfetamina , N-Metil-3,4-Metilenodioxianfetamina/análise , Cabelo/química , Reprodutibilidade dos Testes
20.
Anal Chim Acta ; 1235: 340531, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36368821

RESUMO

The disaster and devastation from abuse of Methamphetamine (MAMP) have a serious impact on people's mental and physical health. Developing a rapid and accurate method to screen drug suspects and thus control MAMP abuse is essential to social security. Hair analysis for MAMP detection is considered to be one of the most potential methods for monitoring drug abuse due to its convenient sample collection, easy for storage and long traceability period. However, the current accurate detection of MAMP in hair primarily utilizes hyphenated mass spectrometry (MS) techniques, but it is not suitable for field-based detection due to the bulky instrument. Hence, developing alternative portable detection techniques for rapid on-site detection of MAMP in hair is an urgent problem to be solved. Here, the high-performance Au nanocakes (Au NCs) were constructed as surface-enhanced Raman spectroscopy (SERS) substrates to detect MAMP in hair, realizing 5 min ultrafast and ultrasensitive detection utilizing a portable Raman spectrometer. Experiments and finite-difference time-domain (FDTD) simulations show that Au NCs have stronger enhancement than Au nanospheres (Au NPs), and 0.5 ppb (3.35 × 10-9 M) MAMP standard is stably detected by Au NCs as an enhanced substrate. A strategy of liquid-liquid microextraction was exploited to eliminate the interference of complex matrices in hair. This method exhibited excellent reproducibility and temporal stability across different drug addicts (relative standard deviation was 5.14% within 160 s). Our approach shows great promise in public safety, providing a rapid and accurate method to detect in hair by SERS.


Assuntos
Nanopartículas Metálicas , Metanfetamina , Humanos , Metanfetamina/análise , Análise Espectral Raman/métodos , Reprodutibilidade dos Testes , Cabelo/química , Espectrometria de Massas , Ouro/química , Nanopartículas Metálicas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...